您的位置:首页 > 产品中心 > hGH ELISA
hGH ELISA
产品编号: | 4157319 |
规格: | sufficient for 192 tests, >98% (SDS-PAGE), kit of 1, suitable for ELISA |
包装规格: | 192 TESTS |
产品类别: | 进口试剂 |
品牌: | Roche |
优惠价: | 立即咨询 |
产品别名
hGH ELISA
ELISA
产品性质
Quality Level【质量水平】 | 100 |
Assay【测定】 | >98% (SDS-PAGE) |
usage【用途】 | sufficient for 192 tests |
manufacturer/tradename | Roche |
technique(s) | ELISA: suitable |
shipped in【运输】 | wet ice |
storage temp.【储存温度】 | 2-8℃ |
packaging【包装】 | 1 kit containing 9 components. |
基本信息
General description【一般描述】 | The hGH assay system differs from most of the other commonly used reporter proteins (CAT, β-Gal, or luciferase) in one important respect: hGH is a secreted protein, and is measured using samples of culture-medium supernatants thus (i) avoiding the necessity to lyse cells, (ii) allowing continuous monitoring of transient expression kinetics, and (iii) allowing use of the cells for other purposes (e.g., RNA isolation). Additionally, hGH is a mammalian gene that may contribute to the apparent high stability of the hGH mRNA in most mammalian cells. Using the standard isotopic protocol, secretion of hGH protein into the culture-medium supernatant can be monitored approximately 24hours post-transfection, depending on the cell type and the sensitivity of the assay used. Usually, hGH is quantified by an immunoradiometric assay (IRMA), resulting in a linear range of approximately 0.1 to 50ng hGH/ml. Human growth hormone (hGH) is specifically detected by the hGH ELISA. It does not cross-react with rat growth hormone. Cross-reactivity with the human homologues TSH, FSH, and LH has not been tested. The hGH protein from E. coli, included in the kit for the purpose of compiling a standard calibration curve, is provided with lot-specific content data as determined by immunoassay. hGH Standards The hGH protein from E. coli, included in the kit for the purpose of compiling a standard calibration curve, is provided with lot-specific content data as determined by immunoassay. |
Specificity【特异性】 | The hGH ELISA specifically detecs human growth hormone (hGH). It does not cross-react with rat growth hormone. |
Application【应用】 | For research use only. Not for use in diagnostic procedures. The hGH ELISA is used to quantitatively measure the expression level of hGH released into cell culture supernatant of eukaryotic cells transfected with a plasmid containing a reporter gene that encodes for hGH. |
Features and Benefits【特点和优势】 |
|
Specifications【产品规格】 | Assay time: Approximately 4 hours Sample material: Culture supernatant Sensitivity: ≥5pg/ml (≥1pg/well) Standards: The hGH protein from E. coli, included in the kit for the purpose of compiling a standard calibration curve, is provided with lot-specific content data as determined by immunoassay. |
Principle【原理】 | The hGH ELISA is based on the sandwich ELISA principle. Antibodies to hGH (anti-hGH) are prebound to the surface of the microplate. The culture supernatant, which contains secreted hGH, is added to the wells of the microplate modules. All hGH contained in the medium binds to the anti-hGH bound to the microplate surface. Next, a digoxigenin-labeled antibody to hGH (anti-hGH-DIG) is added, then bound to hGH. In the following step, an antibody to digoxigenin conjugated to peroxidase (anti-DIG-POD) is added, then bound to digoxigenin. In the final step, the peroxidase substrate ABTS is added. The peroxidase enzyme catalyzes the cleavage of the substrate, yielding a colored reaction product. The absorbance of the sample is determined using an ELISA reader, and is directly correlated to the level of hGH present in the medium supernatant. The sensitivity of the assay can be enhanced using the peroxidase substrate (ABTS) with substrate enhancer. |
Preparation Note【制备说明】 | Working solution: Solution 1 hGH Stock Solution (bottle 1) Reconstitute the lyophilizate in 0.5 ml double distilled water. The resulting concentration is calculated using the lot-specific information, given on the label (final conc. approx 10 ng/ml). This solution is used for the preparation of hGH standards for establishing a hGH calibration curve (see 7.2: preparation of hGH standards). Solution 2 Anti-hGH-DIG (bottle 2) Reconstitute the lyophilizate in 0.5 ml double distilled water (final conc. 100 μg/ml). Solution 2a Anti-hGH-DIG, working dilution To prepare anti-hGH-DIG working dilution, dilute the reconstituted anti-hGH-DIG solution (100 g/ml) with sample buffer (solution 7) to a final conc. of 1 μg/ml (e.g., 100 μl of reconstituted anti-hGH-DIG solution 9.9 ml of solution 7 for 50 wells).The working dilution should be prepared freshly before use and should not be stored. Solution 3 Anti-DIG-POD (bottle 3) Reconstitute the lyophilizate in 0.5 ml double distilledwater (final conc. 20 U/ml). Do not add sodiumazide! Solution 3a Anti-DIG-POD, working dilution To prepare anti-DIG-POD, working dilution, dilute the reconstituted anti-DIG-POD solution (20 U/ml) with sample buffer (solution 7) to a final conc. of 200 mU/ml (e.g., 100 μl of reconstituted anti-DIG-POD solution 9.9 ml of solution 7 for 50 wells). The working dilution should be prepared freshly before use and should not be stored. Solution 4 POD Substrate (bottle 4) Ready-to-use solution. Solution 5 POD Substrate containing Substrate Enhancer (bottles 4 and 5) If a low hGH concentration in the sample is expected, add 1 mg of substrate enhancer (bottle 5) per ml of solution 4 and mix by stirring for 30 min at 15 to 25 ℃. The solution is stable for only 2 hours and should therefore be prepared immediately before use. Use the substrate enhancer only if the hGH concentration is low! Solution 6 Washing Buffer, 1× (bottle 6) To prepare a ready-to-use washing buffer, mix 1 part 10x washing buffer concentrate (bottle 6) with 9 parts of double distilled water. Solution 7 Sample Buffer (bottle 7) The solution is ready-to-use. Mix thoroughly before use. Do not add sodium azide. Storage conditions (working solution): Solution 1 hGH Stock Solution (bottle 1) The reconstitutedsolution is stable for 2 months at 2 to 8 ℃. For long term storage, store in aliquots at or below -15 to -25 ℃. Solution 2 Anti-hGH-DIG (bottle 2) The reconstituted solution is stable for two months at 2 to 8 ℃. For long term storage, store in aliquots at or below -15 to -25 ℃. Solution 2a Anti-hGH-DIG, working dilution The working dilution should be prepared freshly before use and should not be stored. Solution 3 Anti-DIG-POD (bottle 3) The reconstituted solution is stable for 6 months at 2 to 8 ℃. Do not freeze! Solution 3a Anti-DIG-POD, working dilution The working dilution should be prepared freshly before use and should not be stored. Solution 4 POD Substrate (bottle 4) The solution is stable until the expiration date given on the label if stored at 2 to 8 ℃. POD Substrate containing Substrate Enhancer (bottles 4 and 5) The solution is stable for only 2 hours and should therefore be prepared immediately before use. Solution 6 Washing Buffer, 1× (bottle 6) The reconstituted solution is stable for 6 months at 2 to 8 ℃. Solution 7 Sample Buffer (bottle 7) After opening the bottle we recommend storing the solution in aliquots at -15 to -25 ℃, since it does not contain a preservative agent. |
Analysis Note【分析说明】 | No cross-reaction with rat growth hormone. Cross reactivity with the human homologues TSH, FSH, and LH has not been tested. |
Other Notes【其他说明】 | 仅用于生命科学研究。不可用于诊断。 |
Components【组分】 | 组份不可单独销售 hGH (human growth hormone) Anti-hGH-digoxigenin (anti-hGH-DIG) antibody, lyophilizate Anti-Digoxigenin-POD antibody, lyophilizate POD Substrate ready-to-use Substrate Enhancer Washing Buffer 10x concentrated Sample Buffer Microplates (24x8 wells), precoated with anti-hGH (2) Self-adhesive Plate Cover Foils (6) |
安全信息
Pictograms【象形图】 | GHS07 |
Signal word【警示用语:】 | Warning |
Hazard Statements | H317 - H319 - H412 |
Precautionary Statements | P261 - P273 - P280 - P333 + P313 - P337 + P313 - P362 + P364 |
Hazard Classifications【危险分类】 | Aquatic Chronic 3 - Eye Irrit. 2 - Skin Sens. 1 |
Storage Class Code【储存分类代码】 | 12 - Non Combustible Liquids |
WGK | WGK 2 |